티켓 #5226 (new 개선사항)

작성된 시간 : 3 달 전

Why Low Voltage Power Line Succeeds

작성자: ThomasBfs75047 담당자: somebody
Priority: 사소한 Milestone: 마일스톤2
Component: 콤포넌트2 Version: 1.0
Keywords: low voltage power line low voltage power line low voltage power line Cc:

상세한 설명

<br> The mission is estimated to value $111 million, and this value will likely be handed on to the ratepayers of NJ via electric price increases on monthly bills. Furthermore, the price of resistors and isolators are much less as compared to that of the transformers. In addition, low voltage power line the transformer-less method is the smaller dimension as compared with that of transformers to enable a compact kind factor design. One widespread approach to achieve that's to make use of voltage and present transformers. Another advantage of using resistors and optically coupled isolators is the fact that voltage and present sensing's cannot be tampered as in the case of transformers by putting a strong exterior magnets within the shut proximity as to saturate the transformer cores. A transformer-less technique and system for voltage and current sensing using voltage drops across resistors is disclosed. A smart meter system voltage and present sensing are performed as voltage drops throughout a shunt resistor in collection with the power line or from a voltage divider related throughout the power lines. FIG. 3 is an illustration of circuit design for a present sensing portion of voltage and present sensors 39 within the good meter 3 of FIG. 2 for a single-section power line system.<br>

<br> FIG. 1 is an illustration of the good meter system 50 in accordance with an embodiment. FIG. 5 is an illustration of circuit for voltage sensing transistor in an emitter follower configuration with a load resistor linked to the emitter. An optical transistor 12 has a base terminal B that's optically coupled to the IF LED which is a low voltage portion 102. The collector terminal C is connected to the VDD terminal 11. The emitter terminal E is connected to the first terminal of a resistor RL 13 in an emitter follower configuration. An optical transistor 57 has a base terminal B that's optically coupled to the IF LED which is a low voltage portion 102. The collector terminal C is related to the VDD terminal 56. The emitter terminal E is related to the first terminal of a resistor RL 58 within the emitter follower configuration. However, a direct present sensing will be simply finished by measuring the voltage drop across a small shut resistor linked in collection with the facility line. The power usage might be accessed for example by displaying net pages using any system that's linked to the local server or the internet.<br>

<br> Pat. No. 9,000,753, entitled "SMART METER VOLTAGE AND Current SENSING Using OPTICALLY COUPLED ISOLATORS", which is included herein by reference. Using optically coupled isolators, the sensed voltages within the excessive voltage energy strains are optically coupled and electrically remoted to the low voltage circuits. Please share this petition and our Facebook Cause Page with any local teams on fb, Twitter, or through e-mail and Tell Everyone NO MONSTER Power Lines IN MY Backyard! In the event you'd like to donate to our cause Click Here to access our paypal donation link. National Grid released a press release, noting that shifting sediment is the cause for the strains publicity, but added that they're "confident" it's secure. Please see our Facebook Cause Page for particular medical analysis and citations. You may still see the yellow protecting wrapped across the 37,500-volt National Grid powerline that runs the juice generated by the Deepwater Wind turbines through a buried junction box, to the mainland, and the electricity back again to island ratepayers. "That's one thing that National Grid is evaluating right now when it comes to we've communication panels which might be on the seashore house as we speak, simply explaining the problems regarding the cable concern, of a no anchor zone that you see out there, and trying to forestall something from occurring that we would not need to occur," Roberge said.<br>

<br> A Deepwater Wind spokesperson said the lines from the turbines to the island are positive, including that National Grid strains at State Beach have introduced out Grid employees to find a solution. We share the general public's concern about this visibility, which has been attributable to the significant amount of sediment that has been misplaced in the world up to now several months," National Grid famous. The statement went on to notice that throughout "the previous yr, we now have performed monthly surveys of the sediment protection of the cable, which have indicated a significant shifting of sediment and loss of sand on Crescent Beach. "While we share the concern about public safety, we are assured that the cable itself is, as it all the time has been, secure even if not totally covered by sediment. From what we understand, different elements of Block Island are also seeing a significant loss of sediment on account of excessive weather.<br>

첨부파일들


티켓 #5226 에 대해 내용을 추가 및 변경하기
(Why Low Voltage Power Line Succeeds)




티켓에 대한 정보
티켓에 대한 동작